- Model : SUA1000I-IN
- Power Rating : 1000VA (1KVA)
- Output power Max : 670Watts
- UPS Type : Line Interactive
- Waveform : Sine wave
- Battery Type : Built-in Battery
- Backup Time : 6Min to 100Min
- Nominal Output Voltage : 230V
- Nominal Input Voltage : 230V
- Input Connections : IEC-320 C14
- Output Connections : IEC 320 C13
- Application : Computers and Mixed Load
- Warranty : 2 years repair or replacement
1KVA SUA1000I-IN Features
- Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Resettable circuit breakers
Enables a quick recovery from overload events.
- Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
- Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
- Disconnected battery notification
Warns when a battery is not available to provide backup power.
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
- Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
- Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
- LED status indicators
Quickly understand unit and power status with visual indicators.
- Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
- Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
- Disconnected battery notification
Warns when a battery is not available to provide backup power.
- USB connectivity
Provides management of the UPS via a USB port (not available on all models).
- Serial connectivity
Provides management of the UPS via a serial port
1KVA SUA1000I-IN Technical Specifications
Rear Side Image : |
||||||||||||||||||||||||||||||||||||